HYDROSTATIC TEST
The fittings are kept under pressure for 15 seconds when
they are struck moderately with a 700 gm. hammer. The fittings
withstand the pressure test without showing any leakage,
sweating or other defect of any kind.
HYDROSTATIC TEST PRESSURE FOR FITTINGS
|
SIZE
|
1) Fitting without branches
2) Fitting with branches not greater than half the principal
diameter (kgf/cm )
|
Fitting with branches greater than half the
principal diameter (kgf/cm)
|
|
80 to 300
|
25
|
25
|
|
350 to 600
|
20
|
15
|
|
700 to 1500
|
15
|
10
|
TOLERANCE
Length
I. Socket fittings &
Tailpieces
i) Upto 450 mm 20mm
ii) Above 450 mm + 20 mm
- 20 mm
II. Flanged
fittings
All Diameter + 10mm
Mass
I. i) Non Standard fittings
ii) Fittings with more than one
branch
+ 12 percent
iii) Bends
II. Other Standard
fittings
8 percent